Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
JMIR Mhealth Uhealth ; 11: e53291, 2023 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-38153797

RESUMO

Background: Neonatal jaundice (NNJ) or hyperbilirubinemia is a ubiquitous condition in newborn infants. Currently, the transcutaneous bilirubinometer is used to screen for NNJ in health care facilities, where neonates need to be physically present (ie, a centralized model of care for NNJ screening). Mobile health (mHealth) apps present a low-cost, home-based, and noninvasive system that could facilitate self-monitoring of NNJ and could allow mothers the convenience of screening for NNJ remotely. However, end users' acceptability of such mHealth apps is of fundamental importance before the incorporation of such apps into clinical practice. Objective: The study aimed to explore the perception of postpartum mothers toward self-monitoring of NNJ using a novel mHealth app. Methods: Mothers attending video consultations for early postpartum care at 2 Singapore primary care clinics watched an instructional video for a hyperbilirubinemia-screening mHealth app (HSMA). An independent researcher used a semistructured topic guide to conduct in-depth interviews with 25 mothers, assessing their views on HSMAs. All interviews were audio recorded, transcribed verbatim, and checked for accuracy before data analysis. Two researchers independently analyzed the transcripts via thematic analysis. Data were managed using NVivo qualitative data management software. Results: The identified themes were grouped under perceived usability and utility. Mothers valued the convenience and utility of HSMAs for remote monitoring of NNJ. They appreciated the objectivity the app readings provided compared to visual inspection. However, they perceived that the app's applicability would be restricted to severe jaundice, were concerned about its accuracy and restriction to the English language, and lacked confidence in using it. Nevertheless, they were willing to use it once its accuracy was proven and when they received adequate guidance from health care professionals. They also suggested including an action plan for the measured readings and clinical signs within the app. Mothers proposed pairing teleconsultations with HSMAs to boost their confidence and enhance adoption. Conclusions: Mothers were receptive to using HSMAs but had concerns. Multiple languages, proof of accuracy, and resources to guide users should be incorporated into the app in the next phase to increase its successful adoption. Complementing such apps with a teleconsultation service presents a plausible and pragmatic NNJ care delivery model in general practice.


Assuntos
Icterícia Neonatal , Aplicativos Móveis , Feminino , Recém-Nascido , Humanos , Icterícia Neonatal/diagnóstico , Pesquisa Qualitativa , Hiperbilirrubinemia , Período Pós-Parto
2.
J Paediatr Child Health ; 59(2): 288-297, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36440650

RESUMO

AIM: Neonatal jaundice is an important and prevalent condition that can cause kernicterus and mortality. This study validated a smartphone-based screening application (Biliscan) in detecting neonatal jaundice. METHODS: A cross-sectional prospective study was conducted at the neonatal unit in a tertiary teaching hospital between August 2020 and October 2021. All babies born at the gestation of 35 weeks and above with clinical jaundice or are recommended for screening of jaundice within 21 days of post-natal age were recruited. Using Biliscan, images of the babies' skin over the sternum were taken against a standard colour card. The application uses feature extraction and machine learning regression to estimate the bilirubin level. Independent Biliscan bilirubin estimates (BsB) were made and compared with total serum bilirubin (TSB) and transcutaneous bilirubin (TcB) levels. Bland Altman plots were used to establish the agreement between BsB and TSB, as well as TcB, using the clinically acceptable limits of agreement of ±35 µmol/L, which were defined a priori. Pearson correlation coefficient was assessed to establish the strength of the relationship between BsB versus TSB and TcB. Diagnostic accuracy was assessed through receiver operating characteristic curve analysis. RESULTS: Sixty-one paired TSB-BsB and 85 paired TcB-BsB measurements were obtained. Bland Altman plot for the entire group showed that 54% (33/61) of the pairs of TSB and BsB readings and 66% (56/85) of the pairs of TcB and BsB readings were within the maximum clinically acceptable difference of 35 µmol/L. Pearson r for BsB versus TSB and TcB was 0.54 (P < 0.001) and 0.66 (P < 0.001) respectively. Compared with TSB, the recommended gold standard measure for jaundice, Biliscan has a sensitivity of 76.92% and specificity of 70.83% for jaundice requiring phototherapy. The positive and negative predictive values in term infants were 93.3% and 36.9%, respectively. CONCLUSION: Our results suggest that there is moderate correlation and mediocre agreement between BsB and TSB, as well as TcB. Improvement to the application algorithm and further studies that include a larger population, and a wider range of bilirubin values are necessary before the tool may be considered for use in screening of jaundice in newborns.


Assuntos
Icterícia Neonatal , Icterícia , Lactente , Recém-Nascido , Humanos , Icterícia Neonatal/diagnóstico , Estudos Prospectivos , Smartphone , Estudos Transversais , Bilirrubina , Triagem Neonatal/métodos
4.
BMC Pregnancy Childbirth ; 22(1): 317, 2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35418029

RESUMO

The SARS-CoV-2 pandemic is rapidly evolving and remains a major health challenge worldwide. With an increase in pregnant women with COVID-19 infection, we recognized an urgent need to set up a multidisciplinary taskforce to provide safe and holistic care for this group of women. In this review of practice in a tertiary hospital in Singapore, we discuss the key considerations in setting up an isolation maternity unit and our strategies for peripartum and postpartum care. Through teleconsultation, we involve these women and their families in the discussion of timing and mode of birth, disposition of babies after birth and safety of breastfeeding to enable them to make informed decisions and individualize their care.


Assuntos
COVID-19 , Feminino , Humanos , Pandemias/prevenção & controle , Gravidez , Gestantes , SARS-CoV-2 , Centros de Atenção Terciária
6.
BMJ Case Rep ; 14(4)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33863770

RESUMO

A Chinese male infant was born at 35 weeks weighing 2935 g to a mother with polyhydramnios and prenatal hydrops fetalis. He developed marked respiratory distress secondary to bilateral congenital chylothorax and required pleural drainage, high frequency oscillation and inhaled nitric oxide therapy. He was extubated to non-invasive ventilation by day 14. There was no bacterial or intrauterine infection, haematologic, chromosomal or cardiac disorder. He was exclusively fed medium-chain triglyceride formula. High-resolution CT showed diffuse interstitial lung disease. He received a dexamethasone course for chronic lung disease to facilitate supplemental oxygen weaning. A multidisciplinary team comprising neonatology, pulmonology, haematology, interventional radiology and thoracic surgery considered congenital pulmonary lymphangiectasia as the most likely diagnosis and advised open lung biopsy, lymphangiography or scintigraphy for diagnostic confirmation should symptoms of chylothorax recur. Fortunately, he was weaned off oxygen at 5 months of life, and tolerated human milk challenge at 6 months of life and grew well.


Assuntos
Quilotórax , Hidropisia Fetal , Doenças Pulmonares Intersticiais , Quilotórax/complicações , Quilotórax/congênito , Quilotórax/diagnóstico , Humanos , Hidropisia Fetal/etiologia , Recém-Nascido , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/diagnóstico , Masculino
7.
Singapore Med J ; 62(7): 341-346, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-31820009

RESUMO

INTRODUCTION: Congenital heart disease (CHD) is a leading cause of infant mortality. The aim of this study was to evaluate the efficacy of a neonatal screening programme for CHD before the introduction of pulse oximetry. METHODS: This was a retrospective review of live births in the period 2003-2012. Cases of CHD were detected through prenatal ultrasonography and/or postnatal examination, and confirmed using two-dimensional echocardiography. Data was rigorously checked against multiple sources. The antenatal detection rate, sensitivity, specificity, predictive values and likelihood ratios of the screening programme were analysed for all cases of CHD and critical CHD. RESULTS: The incidence of CHD was 9.7 per 1,000 live births. The commonest CHD was ventricular septal defect (54.8%). The antenatal detection rate was three times higher in the critical CHD group (64.0%) compared to the group as a whole (21.1%). The sensitivity and specificity of screening was 64.5% and 99.7% for all CHD, and 92.9% and 99.1% for the critical CHD group, respectively. The positive likelihood ratio was 215 and 103, while the negative likelihood ratio was 0.36 and 0.07 for all CHD and critical CHD, respectively. CONCLUSION: The CHD screening programme had excellent specificity but limited sensitivity. The high positive likelihood ratios indicate that where sufficient risk factors for CHD are present, a positive result effectively confirms the presence of CHD. The low negative likelihood ratio for critical CHD indicates that, where prior suspicion for critical CHD is low, a negative result is reassuring.


Assuntos
Cardiopatias Congênitas , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/epidemiologia , Humanos , Recém-Nascido , Triagem Neonatal/métodos , Oximetria/métodos , Gravidez , Sensibilidade e Especificidade , Singapura/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA